MULTIMETERS/NETWORK RECORDERS iMC3X0
Measuring centers iMC3x0 are intended for monitoring and measuring electrical quantities of single and three-phase electric energy systems. It measures true TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
- It records energy like the electricity meter in all four quadrants in up to four tariffs.
- Since it also measures active and reactive power in all directions it can provide data about power direction (like ANSI code 32).
- By using input/output modules it is possible to use meter for process control. Meter supports 2 optional I/O slots ready for use with double input or output modules.
- Available options are analogue output, digital output (open collector (SO) or mechanical relay) or tariff input. Digital output can be used as pulse or alarm output.
Alarms are a useful tool for fast detection of exceeded parameters, monitoring proper magnitude level, and notification in combination with alarm (relay) outputs. Thus function can be used for secondary over/under voltage/frequency protection, overload protection switch.
Internal memory (8MB) is used for recording of real time measurements and alarms, all equipped with a time stamp.
Various types of communication modules are available. Serial RS485, M-Bus can be used for connecting device in to the network, standard USB and serial RS232 for connection of device to computer or controller and service USB communication (not galvanic separated) that can be used for a fast set-up without need for auxiliary power supply.
Available combinations, supported functions and types can be seen in options table.
Special “ship version” is available, certified by Bureau Veritas.
- Measurements of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, etc.).
- Harmonics measurements up to 31st harmonic.
- Measurements of minimum and maximum values.
- 8 MB flash memory for recorder (iMC350 only).
- 4 Energy counters.
- Accuracy class U, I, P … 0.5.
- Active energy Class 0.5S.
- Frequency range from 16 Hz to 400 Hz.
- Up to 4 I/O (two modules with 2 I/O):
- tariff inputs, 2 digital inputs, 2 digital outputs (SO or relay) or 2 analogue outputs.
- AC or Universal (option) power supply.
- Graphical LCD; 128 x 64 dots with illumination.
- Automatic range of nominal current (max. 12.5 A) and voltage (600 VL-N).
- User-adjustable display of measurements.
- Multilingual support.
- Isolated communication RS485 or RS232 up to 115.200 bit/s, USB 2.0.
- MODBUS, DNP3, M-Bus communication protocol supported.
- Tropical version according to DIN EN 40040.
- MiQen – user-friendly
-
Contact Sales
E-mail Contact card -
Technical Documentation
Users manual iMC3x0 PDF 5,369 kB Data sheet iMC330__iMC350 PDF 2,627 kB -
Certificates